-------------------------------------------------------------------------- Setup hints for using BGFAX, PC Board 15.22, US Robotics Modems 03-10-97 B.J. Guillot bgfax@blkbox.com FidoNet 1:106/400 http://www.blkbox.com/~bgfax/ -------------------------------------------------------------------------- NOTE: US Robotics owners, please read over the USR section in the READ.ME file before proceeding! Please make sure the following two items are true before proceeding... (1) DIP switch #5 is in the "SUPPRESS AUTO ANSWER" position (2) You have already put all relevant DATA commands for the BBS into NVRAM Note that, generally, fax (AT+F) commands CANNOT be stored in NVRAM. Run PCBSETUP.EXE and make the following changes in the modem section... (Do not use PCBMODEM.) Make the following changes... Init-1 ATZ^M~~ATS0=0+FCLASS=2.0 Init-2 AT+FNR=1,1,1,1;+FLI="713 555 1212" Offhook ATH1M0 Answer AT+FAA=1;A Dialout AT+FCLASS=0DT If your BOARD.BAT file (or, whatever the file is that starts up your BBS), after the PCB.EXE line... pcb.exe if errorlevel 7 rcvfax.bat (If you have any other "if errorlevel" lines in your BOARD.BAT, remember that errorlevel numbers must be in DESCENDING order: 9,8,7,6,5, etc.) Make a new file called RCVFAX.BAT that says the following: @echo off bgfax /fco:4 c:\bgfax 1 z board.bat The "1" is for COM1. Change that if necessary for your modem. If you are using PC Board/2 and BGFAX/2 (OS/2 executables), instead of the "1" for COM1, you might need "H%pcbhandle%" or "V1" depending upon what version of PC Board/2 you are using. The "H" tells BGFAX that instead of a port number, a port handle follows. The "V" tells BGFAX to open the port followed by the "V" in VBBS-compatability mode, which is needed on some of the newer versions of PC Board/2. Example: bgfax2 /fco:4 c:\bgfax v1 z P.S... USR's FAX/ARQ light WILL flash when waiting for calls! Regards, bgfax author